Skip to main content

ConceptWall 86 Functional

Technical information

Performance

Energy

Thermal insulation - Uf
3.9 W/m²K

Comfort

Air tightness
AE 900 (900Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class A5 (2000Pa)

Safety

Burglar resistance
RC2
Impact resistance
I5 - E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2000 mm
Min. width of vent
450 mm
Max. width of vent
1500 mm
Max. weight of vent
150 kg
Min. intertia mullion - Ix
114.8 cm4
Max. intertia transom - Ix
435.83 cm4
Min. intertia transom - Iy (glass load)
51.6 cm4
Max. intertia transom - Iy (glass load)
153.38 cm4

Sightlines

Min. width T-profile
86 mm
Min. visible width (interior view)
86 mm
Min. visible width (exterior view)
68 mm
Min. depth mullion
195 mm
Min. depth transom
195 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing - Siliconized glazing - External glazing - Glazing bead
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
38 mm